B. PARAMETERS
B--65245EN/02
APPENDIXES
182
#7 #6 #5 #4 #3 #2 #1 #0
001 EPEXB EPEXA N405 SSL1 HOT ZRTN
Size : 1 byte (bit type)
Standard value :0
ZRTN Specifies whether an alarm is to be issued if a reference
position is not set up, as follows:
0 : An alarm is issued.
1 : An alarm is not issued.
HOT Specifies whether the overtravel direct input signals
(*+OT and *--OT) are valid, as follows:
0 : Invalid
1 : Valid
SSL1 Specifies whether stored stroke limit 1 is valid, as
follows:
0 : Invalid
1 : Valid
NOTE
This parameter is invalid until reference position return is
completed.
N405 Specifies whether a servo alarm is to be issued if reference
position cannot be executed correctly, as follows:
0 : A servo alarm is issued. (No. 405)
1 : A servo alarm is not issued.
NOTE
If a value in the range of 4 to 96 is set for parameter No. 032
(CMR), servo alarmNo. 405 may be issued during reference
position return. In this case, p revent the alarm from being
issued by setting N405 to “1”.
EPEXA, EPEXB
Specify the operation that is to occur if the axis movement
rate determined according to external pulses exceeds the
feedrate upper limit specified in parameter No. 43.
EPEXB EPEXA Description
0 0 The feedrate is clamped to the parameter--specified
value, and the excessive pulses are treated as accumu-
lated pulses.
If the number of accumulated pulses exceeds 99999999,
the excessive pulses are discarded.
0 1 Alarm 291 is detected, leading to deceleration and stop.
1 0 The feedrate is clamped to the parameter--specified
value, and the excessive pulses are discarded.
1 1 Alarm 291 is detected, leading to deceleration and stop.
B.2
COORDINATE
SYSTEM AND
STROKE LIMIT
PARAMETERS