4. OPERATION CHECK METHOD
B--65245EN/02
START--UP PROCEDURE
24
1. Tu rn on the power.
2. The LED indicates -- (minus).
Refer to the explanation of troubleshooting in Part III.
When the LED indicate s data other than -- or 0
3. The emergency stop state is released.
4. The LED indicates 0 (zero).
Check the *ESP signal applied to the servo amplifier unit.
Check the *ESP signal applied through the I/O link.
The LED does not indicate 0.
5. Issue a command from the host controller.
6. Check the operation of the servo motor.
Refer to the explanation of trouble-
shooting in Part III.
An alarm is issued.
Check the command.
Check the parameter settings.
Check *RILK applied to the servo amplifier unit.
The motor does not rotate.
The motor malfunctions.
Refer to Chapter 3 “∼ Series Parameter Adjustment” in the ”FANUC
AC Servo Motor ∼ Series Parameter Manual (B--65150E).”
4.1
CHECK PROCEDURE