B--65245EN/02
2. SIGNAL DESCRIPTIONSHANDLING
55
(4) Command data 2
[Classification]
Output signal <Yy+3 to Yy+6>
[Function]
The host sets command data 2 to specify the amount of movement for
peripheral equipment control.
[Output condition]
See the timing chart of each function code for the corresponding
output timing. See Sections 3.3 and 3. 4 for details.
(5) Response data
[Classification]
Input signal <Xx+3 to Xx+6>
[Function]
A) The servo amplifier unit outputs t he current position number
(point, turret, or magazine number) for point or ATC control. This
response data is set up upon the completion of positioning. The
servo amplifier unit continues to output the previous number
until the new response data is set up.
B) Machine coordinates, workpiece coordinates, or motor current
value can be output in real time according to the setting of
parameter No. 020.
C) When the DSAL signal [Subsection 2.3.13.(9)] is 1, the servo
amplifier unit outputs the number of alarms and the first alarm
number.
[Input condition]
See the function code command list.