2. SIGNAL DESCRIPTIONS
B--65245EN/02
HANDLING
46
(3 ) Acceleration/deceleration pulse signal SUPX
[Classification]
Input signal <Xx+0#2> (common to both the peripheral equipment
control and direct command interfaces)
[Function]
This signal indicates that the servo amplifier unit has accumulated
pulses in the acceleration/deceleration control section.
[Input condition]
The signal is 1 when:
1. Axis movement distribution pulses are accumulated in the
acceleration/deceleration control section.
The signal is 0 when:
1. No axis movement distribution pulses are accumulated in the
acceleration/deceleration control section.
(4) In--position signal INPX
[Classification]
Input signal <Xx+0#3> (common to both the peripheral equipment
control and direct command interfaces)
[Function]
This signal indicat es that the controlled axis is in position (has
reached the specified value).
[Input condition]
The signal is 1 when:
1. There is no acceleration/deceleration delay (accumulated pulses)
for the controlled axis, and the servo positional deviation i s
within a parameter--specified range.
The signal is 0 when:
1. There is an acceleration/deceleration delay (accumulated pulses)
for the controlled axis, or
2. The servo positional deviation falls outside a
parameter--specified range.
(5) S ervo positional deviation monitor signal S VERX
[Classification]
Input signal <Xx+7#6> (peripheral equipment control interface)
Input signal <Xx+3#6> (direct command interface)
[Function]
This signal indicates that, in the servo amplifier unit, the amount of
servo positional deviation has exceeded a parameter--specified value.
[Input condition]
The signal is 1 when:
1. The servo positional deviation amount is larger than a
parameter--specified value.
The signal is 0 when:
1. A parameter--specified value for the servo positional deviation
amount is 0, or
2. The servo positional deviation amount is within a
parameter--specified range.