B. PARAMETERS
B--65245EN/02
APPENDIXES
194
NOTE
If 0 is set, n o operation completion signal is not output.
167 Time between servo--on and unclamping
Size : 4 bytes
Unit :8ms
Range : 0 to 99999999
Standard value :0
Description : S pecifies a time interval from the time the servo
system is switched on until the machine is unclamped
if clamping/unclamping is used.
168 Time between clamping and servo--off
Size : 4 bytes
Unit :8ms
Range : 0 to 99999999
Standard value :0
Description : S pecifies a time interval from the time the m achine is
clamped until the servo system is switched off if
clamping/unclamping is used.
169 Time allowed before the next sequence is executed without clamping/unclamping
Size : 4 bytes
Unit :8ms
Range : 0 to 99999999
Standard value :0
Description : S pecifies a time interval from the time the
clamp/unclamp command (UCPC2) i s issued until
the next sequence is started, if the clamp/unclamp
state signal (UCPS2) is not to be checked. Whether
to check the clamp/unclamp state signal (UCPS2) is
specified using bit 2 of parameter No. 003 (IGCP).