B--65245EN/02
3. PERIPHERAL EQUIPMENT CONTROLHANDLING
69
NOTE
1 If the remaining distance to the next point is shorter than
the required deceleration distance for stopping at that
point when the feed axis and direction selection switch
(+X, --X) is released, movement is made to the point
immediately after the next point.
2 Set bit 1 (ROTX) of parameter No. 000 (for rotation axis
setting) to 1, and set bit 7 (ROAX) of parameter No. 000 to
1 (for rollover).
3 As the position corresponding to each point number,
workpiece coordinates are set in parameter Nos. 154 to
165.
4 The feedrates of feedrate codes 1 to 7 are set in parameter
Nos. 044 to 050, and a rapid traverse rate is set in
parameter No. 040.
5 In rollover setting, shortcut control is possible. In rollover
setting, set a value within +1 rotation for the absolute
positioning command.
6 When a reference position is set after the power is turned
on, turret/magazine number 1 is output. Before reference
position setting, perform movement by jog operation for a
minimum given distance at a minimum given feedrate
(distance and feedrate for accumulating a servo position
deviation of 128 pulses or more). Then, set function code
4, and command data 1 = 15, and turn on +X/--X to perform
reference position return. If bit 1 (SZRN) of parameter No.
011 is set, the reference position can be shifted one grid
each time +X/ --X is turned on.
7 Normal jog feed operation can be used only when function
code 0, 1, 10, or 15 is specified.
8 When an absolute pulse coder is used, the current position
can b e used as a reference position. After positioning to a
reference position, set function code 4, command data 1
= 15, jog mode, and emergency stop release state, then
turn on the ST signal.
9 In ATC automatic operation mode, the rapid traverse rate
(parameter No. 040) is used unconditionally. In jog
operation mode, the rapid traverse rate (parameter No.
040) is used when the RT signal is turned on. The jog
feedrate (parameter No. 041) is used when the RT signal
is turned off.
10 Never change the current mode during operation. The
mode can be changed only after operation has been
stopped.