B-65245EN/02-8
9/11
EDIT
DATE DESIG.
DESCRIPTION
FANUC SERVO MOTOR β series I/O Link Option
Skip Function (Improvement of the specification) and
CAUTION to the parameters No.068, 141
TITLE
DRAW.NO. CUST.
SHEET
01
04.05.06
Newly added
No #7 #6 #5 #4 #3 #2 #1 #0
017 SPCO HEDG HENB
Size : 1 byte (bit type)
Standard value : 0
HENB : Skip function is
0 : not used.
1 : used.
HEDG : In case of using skip signal (HDI) in the skip function,
0 : rising edge ((0->1) is regarded as signal input.
1 : falling edge (1->0) is regarded as signal input.
SPCO : When the axis arrives at the end point without the skip signal (HDI) input in the skip
function:
0 : Register the before skip position
1 : Register the commanded end position
Please add the following between the description of the parameter No.5 and No.20 in
the B.5 INPUT/OUTPUT SIGNALS PARAMETERS of APPENDIXES B. PARAMETERS.
NOTE
Skip function can be applied only to the amplifier with the following drawing number.
Name Drawing number for order
SVU-12 A06B-6093-H171
SVU-20 A06B-6093-H172
SVU-40 A06B-6093-H173
SVU-80 A06B-6093-H174