B-65245EN/02-8
4/11
EDIT
DATE DESIG.
DESCRIPTION
FANUC SERVO MOTOR β series I/O Link Option
Skip Function (Improvement of the specification) and
CAUTION to the parameters No.068, 141
TITLE
DRAW.NO. CUST.
SHEET
01
04.05.06
Newly added
・
Positioning by skip function
When the function code 8 is specified, skip function by a skip signal (HDI) becomes active. If a skip
signal is input during executing, the axis is stopped immediately and OPC4 signal is output. And the
work coordinate where the skip signal is just input is recorded as measuring data. The host
controller can read this data as response data if the parameter No.20 is set to “5”.
Please add the following between “7. Velocity control” and “10. Coordinate system
setting” in the subsection 3.3.1 Function Codes of II HANDLING 3.PERIPHERAL
EQUIPMENT CONTROL.
Function code Command data 1
4Bit
Command
data 2
4Byte
Mode Start
signal
Remarks
Bit3 Bit0 to 2(Binary)
0 Absolute specification:
Feedrate code 1 to 7
Workpiece
coordinate
Bit3 Bit0 to 2(Binary)
8 :Positioning
(Skip function)
1 Incremental specification:
Feedrate code 1 to 7
Moving
amount
AUTO
ST (CAUTION 4)
Please add the following before “Supplementary information” in the subsection 3.4.5
Positioning Control (Absolute/Incremental Specification) of II HANDLING 3.PERIPHERAL
EQUIPMENT CONTROL.
NOTE
1. If the axis moving arrives to the end point except the skip signal (HDI) input when the skip
function is operated, the kind of registered position can be selected by the paramete
No.17#2(SPCO) setting.(0:Register the before skip position. 1:Register the commanded end
position).
2. When the skip function of the Peripheral Equipment Control is finished, the position reading
must be done after confirming of the OPC4 signal is on.
3. When the skip function is operated, if the axis moving is stopped by the Emergency stop,
reset, alarm, the registered position is not refreshed.