B--65245EN/02
B. PARAMETERSAPPENDIXES
189
#7 #6 #5 #4 #3 #2 #1 #0
003 STON EXPLS WAT2 IGCP NCLP
Size : 1 byte (bit type)
Standard value : 1 only for NCLP
NCLP Specifies whether to use clamping/unclamping, as
follows:
0 : Clamping/unclamping is used.
1 : Clamping/unclamping is not used.
IGCP Specifies whether to check a clamp/unclamp state
(UCPS2) before proceeding to the next sequence, as
follows:
0 : A clamp/unclamp state is checked.
1 : A clamp/unclamp state i s not checked.
WAT 2 Indicates whether an ID code can be specified for a wait
function, as follows:
0 : An ID code cannot be specified.
1 : An ID code can be specified.
EXPLS Indicates whether an axis movement function based on
external pulses (pulses from a manual pulse generator) is
valid, as follows:
0 : Invalid.
1 : Valid.
STON Specifies whether an automatic operation is started at the
rising (off to on) or falling (on to off) edge of the
automatic operation start (ST) signal, as follows:
0 : Falling edge (on to off)
1 : Rising edge (off to on)
#7 #6 #5 #4 #3 #2 #1 #0
004 NEPRM IVO SAK
Size : 1 byte (bit type)
Standard value :0
SAK When the VRDY OFF alarm ignore signal (IGNVRY) is
1:
0:Servoreadysignal(SA)issetto0.
1:Servoreadysignal(SA)remainssetto0.
IVO When an attempt is made to release an emergency stop
while the VRDY OFF alarm ignore signal (IGNVRY) is
1:
0 : The emergency stop is not released.
1 : The emergency stop is released.
CAUTION
When the VRDY OFF alarm ignore signal (IGNVRY) is 1,
and the motor is deenergized, a reset state will be exited
even if a reset signal is input.
B.5
INPUT/OUTPUT
SIGNALS
PARAMETERS