3. INPUT AND OUTPUT OF DATA
B–62755EN/01
190
1. Set to the emergency stop state.
2. Confirm that the patameters required to input data is correct.
1) Press OFFSET/SETTING key several times, and press [SETING]
to display SETTING screen.
2) Confirm that PARAMETER WRITE=1.
3) Press SYSTEM key to select the parameter screen.
4)
0020 Selectionof I/O channel
l 0 : Channel 1 (JD5A of MAIN CPU board)
1 : Channel 1 (JD5A of MAIN CPU board)
2 : Channel 2 (JD5B of MAIN CPU board)
3 : Channel 3 (JD5C of Option 1)
5)
#7
NFD0101
#6 #5 #4 #3
ASI
#2 #1 #0
SB2
#7 (NFD) 0 : Feed is output when punching out.
1 : Feed is not output when punching out.
#3 (ASI) 0 : EIA or ISO code is used.
1 : ASCII code is used.
#0 (SB2) 0 : No. of stop bits is 1.
l 1 : No. of stop bits is 2.
6)
0102 Specification number of I/O device
0 RS–232–C (control codes DC1 to DC4 are used.)
1 FANUC Bubble cassette B1/B2
2 FANUCFloppy cassette F1
3 PROGRAM FILE Mate, FANUC FA Card adapter, FANUC
Floppy casette adapter, FSP–H, FANUC Handy File
4 RS–232–C ( Control codes DC1 to DC4 are not used)
5 Portable tape reader
6 FANUC PPR, FSP–G, FSP–H
3.2.8
Inputting CNC
Parameters