B–62755EN/01
3. INPUT AND OUTPUT OF DATA
197
You can input and output files individually.
Execute the same operations from step 1 to 6 in the previous section 3.3.1.
(1)Reading or Punching default files
7 Press [DEF. FILE].
8 @ For reading, input a file no. for default data and press soft key
[READ EXEC]. (Specify a file number of default file).
@ For punching, press [PUNCH EXEC].
(2)Reading or punching pre–tool list
7 Press PRE–TOOL.
8 @ For reading, press a file number and soft key [READ EXEC].
(Specify a file number of pre–tool list).
@ For punching, press soft key [PUNCH EXEC].
(3)Reading or Punching tool file
7 Press TOOL FILE.
8 @ For reading, press a file number and pres soft key
[READ EXEC]. (Specify file number of tool file).
@ For punching, press [PUNCH EXEC].
(4)Reading or Punching F, S file
7 Press F.S. FILE.
8 @ For reading, press a file no. and press soft key
[READ EXEC].(Specify a file no. of F.S. FILE).
@ For punching, press [PUNCH EXEC].
This feature allows NC parameters, offsets, NC programs, PMC
parameters and so on to be input/output from/to a general I/O device such
as FANUC cassette adapter or the like.
1. Data that can be input/output
(1) NC parameters: All parameters except for optional parameters
and a parameter that specifies the no. of
axes.(No. 1010)
(2) Offset values: All data of wear/geometry data
(3) NC programs: All the NC programs
(4) PMC parameters: All data of counter, keep relay, timer and other
data
(5) Tool File: All data of tool data file, F.S. data, roughness
data, pre–tool list and chuck/tailstock figure
data.
(6) CAP program: All the CAP program (Cannot input/output
individual program)
CAUTION
You should input/output NC parameters separately. You
can input/output other data in a lump.
3.3.2
Input and Output of Each
File
3.3.3
Output of CAP Data
(Super CAP T)