3. INPUT AND OUTPUT OF DATA
B–62755EN/01
202
NC parameter
9090 PMCIOS
PMCIOS
:The start address number of D area of the PMC parameters to be
output.
9091 PMCIOE
PMCIOE
:The end address number of D area of PMC parameters to be output.
No.9090(PMCIOS)=0, No.9091(PMCIOE)=0
: All the PMC parameters including keep relays, counters, timers and data
are output.
No.9090(PMCIOS)=No.9091(PMCIOE) : 0
: D area data (one data) of the specified address number is output.
No.9090(PMCIOS) < No.9091(PMCIOE)
: D area data of PMC parameters from the specified starting address number
to the ending address number are output.
No.9090(PMCIOS) > No.9091(PMCIOE)
: All the data in D area are output.
The data output by the input/output in a lump function mentioned in 3.3.3
can be input in a lump by the following operation;
1. Set optional parameters required and the parameter for setting the
number of axes (parameter no. 1010) beforehand.
2. Connect an I/O device and set the corresponding parameters required
as the same as output operation.
3. Select EDIT mode. Select Head 1 screen for path 2.
4. Release protection according to each data to input.
1) NC parameter : Set setting data “PARAMETER WRITE” to 1.
2) Offset amount : Turn off protection of offset data (KEY1=1).
3) NC program : Turn off program protect (KEY3=1).
4) PMC parameter : Set setting data “PARAMETER WRITE” to 1.
5) Tool File : Turns off offset data protection (KEY1=1)
6) CAP program : Turns off program protect (KEY3=1)
3.3.4
Inputting CAP Data
(Super CAP T)