APPENDIX
B. ALARM LIST
B–62755EN/01
458
Alarm
No.
RemedyDescriptionMeaning
AL–49 The converted differential
speed is too high.
Detects that speed of other spindle converted to
speed of local spindle has exceeded allowable limit
in differential mode.
Calculate differential
speed by multiplying speed
of other spindle by gear ra-
tio. Check if calculated val-
ue is not greater than maxi-
mum speed of motor.
AL–50 Excessive speed command
calculation value in spindle
synchronization control
Detects that speed command calculation value ex-
ceeded allowable range in spindle synchronization
control.
Calculate motor speed by
multiplying specified
spindle speed by gear ra-
tio. Check if calculated val-
ue is not greater than maxi-
mum speed of motor.
AL–51 Undervoltage at DC link sec-
tion
Detects that DC power supply voltage of power cir-
cuit has dropped (due to momentary power failure or
loose contact of magnetic contactor).
Remove cause, then reset
alarm.
AL–52 ITP signal abnormality I Detects abnormality in synchronization signal (ITP
signal ) used in software.
Replace servo amp. PCB.
AL–53 ITP signal abnormality II Detects abnormality in synchronization signal (ITP
signal) used in hardware.
Replace servo amp. PCB.
AL–54 Overload current alarm Detects that excessive current flowed in motor for
long time.
Remove overload of motor
and reset the alarm.
AL–55 Power line abnormality in
spindle switching/output
switching
Detects that switch request signal does not match
power line status check signal.
Check if power line status,
check signal is processed
normally.