APPENDIX
B. ALARM LIST
B–62755EN/01
440
(5) Servo alarms
Number Message Contents
400 SERVO ALARM: n–TH AXIS OVER-
LOAD
The n–th axis (axis 1–8) overload signal is on. Refer to diagnosis dis-
play No. 201 for details.
401 SERVO ALARM: n–TH AXIS VRDY
OFF
The n–th axis (axis 1–8) servo amplifier READY signal (DRDY) went off.
Refer to procedure of trouble shooting.
404 SERVO ALARM: n–TH AXIS VRDY
ON
Even though the n–th axis (axis 1–8) READY signal (MCON) went off,
the servo amplifier READY signal (DRDY) is still on. Or, when the power
was turned on, DRDY went on even though MCON was off.
Check that the servo interface module and servo amp are connected.
405 SERVO ALARM: (ZERO POINT RE-
TURN FAULT)
Position control system fault. Due to an NC or servo system fault in the
reference position return, there is the possibility that reference position
return could not be executed correctly. Try again from the manual refer-
ence position return.
407 SERVO ALARM: EXCESS ERROR The difference in synchronous axis position deviation exceeded the set
value.
409 SERVO ALARM: n AXIS TORQUE
ALM
Abnormal servo motor load has been detected. Alternatively, abnormal
spindle motor load has been detected in Cs mode.
410 SERVO ALARM: n–TH AXIS – EX-
CESS ERROR
The position deviation value when the n–th axis (axis 1–8) stops is larg-
er than the set value.
Refer to procedure of trouble shooting.
411 SERVO ALARM: n–TH AXIS – EX-
CESS ERROR
The position deviation value when the n–th axis (axis 1–8) moves is
larger than the set value.
Refer to procedure of trouble shooting.
413 SERVO ALARM: n–th AXIS – LSI
OVERFLOW
The contents of the error register for the n–th axis (axis 1–8) exceeded
"2
31
power. This error usually occurs as the result of an improperly set
parameters.
414 SERVO ALARM: n–TH AXIS –
DETECTION RELATED ERROR
N–th axis (axis 1–8) digital servo system fault. Refer to diagnosis dis-
play No. 200 and No.204 for details.
415 SERVO ALARM: n–TH AXIS – EX-
CESS SHIFT
A speed higher than 511875 units/s was attempted to be set in the n–th
axis (axis 1–8). This error occurs as the result of improperly set CMR.
416 SERVO ALARM: n–TH AXIS – DIS-
CONNECTION
Position detection system fault in the n–th axis (axis 1–8) pulse coder
(disconnection alarm). Refer to diagnosis display No. 201 for details.
417 SERVO ALARM: n–TH AXIS – PA-
RAMETER INCORRECT
This alarm occurs when the n–th axis (axis 1–8) is in one of the condi-
tions listed below. (Digital servo system alarm)
1) The value set in Parameter No. 2020 (motor form) is out of the speci-
fied limit.
2) A proper value (111 or –111) is not set in parameter No.2022 (motor
revolution direction).
3) Illegal data (a value below 0, etc.) was set in parameter No. 2023
(number of speed feedback pulses per motor revolution).
4) Illegal data (a value below 0, etc.) was set in parameter No. 2024
(number of position feedback pulses per motor revolution).
5) Parameters No. 2084 and No. 2085 (flexible field gear rate) have not
been set.
6) A value outside the limit of {1 to the number of control axes} or a non–
continuous value (Parameter 1023 (servo axis number) contains a
value out of the range from 1 to the number of axes, or an isolated
value (for example, 4 not prceded by 3).was set in parameter No.
1023 (servo axisnumber).