B–62755EN/01
8.TROUBLESHOOTING
371
Reform the following countermeasures based on the above
configurations:
(1)#3(SPE)1: In spindle serial control, the serial spindle parameters does
not satisfy the starting conditions for spindle amplifier.
↓
Confirm the settings of parameters 4000s.
Especially checks the parameters those are changed from the standard
parameters.
(2)#2(S2E)1: At the start of spindle serial control, when an abnormality
is found in the 2nd spindle side.
↓
Check the 2nd spindle parameters and connections to see whether the
spindle is mechanically and electronically connected to the spindle.
↓
If the above settings and connections are right, the module of (4) or the
spindle amplifier itself may be defective.
(3)#1(SIE)1: When an abnormality is found in the 1st spindle at the start
of serial spindle control, exchange the unit if the following
check items are not concerned.
↓
Check the parameters and connections at the 1st spindle to see whether
the 1st spindle is mechanically and electrically connected.
↓
If the parameters and connections are correct, the system control
module shown below or the spindle amplifier itself is faulty.
(4)#0(SPE)1: The serial communication module is detected to be
abnormal. Exchange the following module :
Remedies