APPENDIX
B–62755EN/01
B. ALARM LIST
439
When either of the following alarms is issued, a possible cause is a faulty
serial pulse coder or cable.
Number Message Contents
350 SPC ALARM: n AXIS PULSE COD-
ER
The n axis (axis 1–8) pulse coder has a fault. Refer to diagnosis display
No. 202 and No. 204 for details.
351 SPC ALARM: n AXIS COMMUNICA-
TION
n axis (axis 1–8) serial pulse coder communication error (data transmis-
sion fault)
Refer to diagnosis display No. 203 for details.
#7
202
#6
CSA
#5
BLA
#4
PHA
#3
PCA
#2
BZA
#1
CKA
#0
SPH
#6 (CSA) : Check sum alarm has occurred.
#5 (BLA) : Battery low alarm has occurred.
#4 (PHA) : Phase data trouble alarm has occurred.
#3 (PCA) : Speed count trouble alarm has occurred.
#2 (BZA) : Battery zero alarm has occurred.
#1 (CKA) : Clock alarm has occurred.
#0 (SPH) : Soft phase data trouble alarm has occurred.
#7
DTE203
#6
CRC
#5
STB
#4 #3 #2 #1 #0
#7 (DTE) : Data error has occurred.
#6 (CRC) : CRC error has occurred.
#5 (STB) : Stop bit error has occurred.
(4) Serial pulse coder
(SPC) alarms
D The details of serial
pulse coder alarm
No.350
D The details of serial
pulse coder alarm
No.351