1. DISPLAY AND OPERATION OF CRT/MDI
B–62755EN/01
32
Data displayed on the operation history screen
(1)MDI keys
Address and numeric keys are displayed after a single space.
Soft keys are displayed in square brackets ([]).
Other keys (RESET/INPUT, for example) are displayed in angle
brackets (<>).
A key pressed at power–on is displayed in reverse video.
For two–path control, the operations of path 2 are displayed in the
same way, but preceded by S_.
1) Function key:
POS
,
PROG
,
OFFSET
SETTING
, etc.
2) Address/numeric key: A to Z, 0 to 9, ; (EOB), +, –, (, etc.
3) Page/cursor key:
PAGE
, ,
4) Soft key: [SF1], [SF2], etc.
5) Other key:
RESET
,
CAN
, etc.
6) Key pressed at power–on:
RESET
(2)Input and output signals
Indicates the bit.
General signals are displayed in the following format:
G 0 0 0 0 . 7 ↑
The ↑ mark indicates that the signal is
turned on.
The ↓ mark indicates that the signal is
turned off.
Indicates the address.
Some signals are indicated by their symbol names.
SBK ↑ (Indicates that the single block switch is turned on.)