9. TROUBLESHOOTING (SERIAL INTERFACE SPINDLE)
B–62755EN/01
396
Item Cause of trouble Check procedure Remedy
1
Signal level of spindle
motor for Cs
contouring control is
invalid.
Check the signal, and if necessary adjust to the normal
level using the variable resistor for signal level adjust-
ment in the preamp.
2
Signal line of spindle
motor for Cs contour
control is
defective
Check that signal cable is
connected securely to
connector.
Check that signal cable is
not broken.
Connect signal cable se-
curely.
Replace signal cable.
3
Defective detector cir-
cuit for Cs contour
control
Replace detector circuit.
4
Incorrect parameter
setting
Check that the parameter
setting does not indicate
that the Cs contour
control detector is used
when actually it is not.
Parameter CAXIS1 = 0
No. 4001#5
Item Cause of trouble Check procedure Remedy
1
Position coder signal
line defective
Check that signal cable is
connected securely to
connector.
Check that signal cable is
not broken.
Connect signal cable se-
curely.
Replace signal cable.
2
Incorrect parameter
setting
Check that the parameter
setting does not indicate
that the position coder
signal is used when actu-
ally it is not.
Parameter MRDY2 = 0
No. 4001#2
Item Cause of trouble Check procedure Remedy
1
Signal level of spindle
detector for Cs axis
control is defective
Check the signal level, and if necessary adjust to the
normal level using the variable resistor for signal level
adjustment in the preamp.
2
Signal line of spindle
detector for Cs axis
control is defective
Check that signal cable is
connected securely to
connector.
Check that signal cable is
not broken.
Connect signal cable se-
curely.
Replace signal cable.
3
Defective detector cir-
cuit for Cs axis
control
Replace detector circuit.
Item Cause of trouble Check procedure Remedy
1
Overloaded opera-
tion (Overload)
Use loadmeter to check
that a load close to the
load resistance limit is not
imposed continuously for
30 seconds or more.
Re-examine cutting
conditions and tools.
AL–26 Disconnection of
speed detection
signal for Cs
contouring
control
AL–27 Position coder
signal
disconnection
AL–28 Disconnection of
position detection
signal for Cs
contouring
control
AL–29 Short–time
overload