6.ASSIST GAS CONTROL B-63192EN/03
- 22 -
Flow pattern command
The following pattern of data such as pre-stage pressure and time,
cutting pressure, and post-stage pressure and time is previously
registered as a flow pattern. It can be specified using the Q
address.
Cutting pressure
Time
Pre-stage time
Post-sta
e time
Post-stage pressure
Pre-stage pressure
Specifying P≠0 and Q≠0 in the G32 flow pattern command
opens the shutter, outputs the assist gas selection signals, then
outputs the assist gas pressure analog signal according to the
flow pattern.
Specifying P=0 or Q=0 in G32 closes the shutter, and causes the
assist gas selection signals to quit selecting an assist gas, then
turns off the assist gas pressure analog signal after the post-stage
is generated for the specified post-stage time.
- Format
G32P-(Q-) ;
The parameters enclosed in parentheses is omissible.
P= gas type :
Specifies the assist gas type.
0 : The shutter is closed, and no assist gas is selected.
1 to 7 : The shutter is opened, and an assist gas is
selected.
Q= pattern selection :
Specifies a flow pattern number.
NOTE
The assist gas and shutter are controlled
synchronously. While the assist gas is being output,
therefore, the shutter is open. In this condition, do
not insert your hand below the nozzle.