8.LASER OUTPUT CONTROL B-63192EN/03
- 28 -
8.1.1 Power Value Command and Power Override
The laser power is specified with a value that follows the S address in
a laser output command.
G01 X_Y_F_Sxxxx ;
S : Specifies the power value.
Valid data range : 0 to 7000 W
(*1)
Minimum increment : 1W
(*1) The maximum and minimum values vary with the
model of the oscillator.
When a laser output command is fetched from the program, if the S
address has a specified value, it updates the power value in the laser
data area. The laser data area holds specified values. When a laser
output command is executed, data is read from the laser data area and
sent to the laser oscillator.
The laser data is also displayed on the laser setting screen, and can be
updated using key entries. There are two types of power value laser
data areas: one type for contouring and the other type for piercing.
Power values specified in G01, G02, G03, and G12 are stored in the
laser data area for contouring. A power value specified in G24 is
stored in the laser data area for piercing.
The PMC can override the power value during command execution.
The override value can range between 0 and 200% (in 1% steps).
Contouring
command
G01 Sxxxx;
Key entries
on the screen
Power
values for
contouring
Piercing
command
G24 Sxxxx;
Power
values for
piercing
Override Output
clamp
Ke
entries
on the screen
Power override
Output
command
Laser