8.LASER OUTPUT CONTROL B-63192EN/03
- 34 -
8.1.6 Power Control
The power control function controls the laser output by changing the
actual feedrate. This function is valid when G63P1 is specified (where
the power control for the laser settings is set to 1) and invalid when
G63P0 is specified. To enable or disable this function, an external
signal can also be used.
This function changes the output conditions according to the actual
feedrate, based on the feedrate, power value, pulse frequency, and
duty cycle specified with G63P1 (or when the relevant external signal
is set to 1).
Duty
cycle
Dc
Fc Feedrate
0
Dm
Fc : Feedrate specified in the program
Dc : Pulse duty cycle specified at the
same time with the feedrate in the
program
Dm : Lower limit to the duty cycle
specified in the laser data area
NOTE
This function is valid only for X-Y facing. It cannot
be used with functions for cylindrical machining,
normal direction control, three-dimensional
machining, etc.
8.1.7 High-speed Laser Machining
This function enables high-speed machining using the RISC function.
High-speed
laser machining can be executed using the following three functions:
• Laser command in RISC mode
• Overwrite function for automatic speed control parameters
• Delay control function for laser beam on/off
This function is enabled in RISC mode and disabled in modes other
than RISC. This function is optional. Specify the function with the
RISC function.
NOTE
This function is valid only for X-Y facing. It cannot
be used with functions for cylindrical machining,
normal direction control, three-dimensional
machining, etc.