12.LASER FUNCTIONS OF THE YP SERIES OSCILLATORS B-63192EN/03
- 86 -
12.3.2 Command Format
Setting
Waveform data can be stored in the data area in the CNC, in the
following command format:
G26 P_ K_ I_ ;
- Explanation of the command format
Command Description
P_
Waveform number
One of the numbers assigned to 16 sets of waveform
data.
Valid range: 1 to 16
K_
Step number
A set of waveform data consists of 20 steps.
Valid range: 1 to 20
I_
Current value
Set the current value corresponding to the step
number.
Example of YP1000E
Valid range: 0, 60 to 600A
Increment system: 1A
Note) The value to be specified must be within the
valid range given above for each model.
Transfer
Once stored in the data area of the CNC, waveform data can be
transferred to the oscillator on a set-by-set basis in the following
command format and registered with the controller.
- Explanation of the command format
Command Description
L50
Transfer command
The command specification is required.
P_
Waveform number
Set the waveform data No.
Valid range: 1 to 16