8.LASER OUTPUT CONTROL B-63192EN/03
- 40 -
8.2.4 Executing the Data
(1) Piercing command
When G24 is executed, a data group specified with the E code is
read from the data area to carry out piercing. The E code can be
specified independently.
G24 Exxx ;
Exxx : Piercing data number (101 to 103)
(2) Reading the cutting data
When a cutting feed command is executed, a data group
specified with the E code is read from the data area to carry out
piercing. The E code can be specified independently.
Cutting feed command G01/G02/G03 Exx ;
Exx : Cutting data number (1 to 10)
(3) Switching the assist gas
G32 specifies to switch on/off the assist gas supply and selects
either the piercing assist gas or cutting assist gas. The shutter can
be opened/closed at the same time the assist gas is turned on/off.
A parameter can be used to disable shutter open/close control.
G32 Lx ;
Lx :0=stop assist gas supply.
1=select cutting assist gas.
2=select piercing assist gas.
(4) Using the E code together with the conventional commands
If the S, P, Q, R, F, or D address is used to specify laser output,
feedrate, cutter compensation, or other items during execution
based on the E code, data updating based on the E code is
discontinued, and operation is carried on with the values
specified at these addresses. To resume operation with the data
area, specify the E code again.