B–62073E–1/04 2. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 119 –
When all the selections signals are low, either of the following can be selected by a parameter:
a. The operation mode selected last is kept.
b. The operation mode selected last is kept for a specified time (T0), then neither automatic operation mode
nor manual operation mode is selected. If the selection signals are entered in a specified manner within
T0, the corresponding operation mode is selected.
Time periods T0 and T1 are specified by parameters within the range of 0 to 2 seconds.
Switching the operation mode
When an operation mode is switched to another, the control unit usually operates in one of the following man-
ners:
a. Immediate switching: The control unit immediately stops and resumes the operation in the new mode.
b. Switching at the end of a block: The control unit continues the operation in the current mode until the cur-
rent block terminates. Then, it stops once and resumes the operation in the new mode.
c. Non–stop switching: The control unit enters the new mode without stopping the current operation.
Before stopping, all axis movements are decelerated.
The operation of the control unit depends on the newly selected mode and the previous mode as shown in the
table below.
Newly selected operation mode
Automatic operation
Manual
operation
Auto/manual
simultaneous
operation
(See Note1)
Automatic
operation
Selected when a block
ends
Immediate
selection
Continuance of
operation
Previous
o
eration
Manual
operation
Immediate selection
Immediate
selection
Immediate
selection
mode
Auto/manual
simultaneous
operation
Continuance of operation
in automatic mode and
immediate selection in
manual mode.
Immediate
selection
(See Note 2)
NOTE 1 The operation marked with an asterisk () is not executed in the Series 15–TT.
NOTE 2 When an operation mode concerning automatic operation is switched, the automatic operation
is switched at the end of the current block and the manual operation is continued. When an
operation mode concerning manual operation is switched, the automatic operation is
continued and the manual operation is switched immediately.
While the specified movement is decelerated for immediate switching or while the previous operation is contin-
ued for switching at the end of the current block, the system does not assume that the new mode is selected.
During this period, the output signal indicates that the previous operation mode is selected.
(a) Manual data input selection signal: D
[Classification]
Input signal
[Function] Selects the manual data input operation mode. Executes data input from the MDI panel or
tape and automatic operation according to the command program entered from the MDI pan-
el.
[Operation] See the descriptions of “Selecting the Operation Mode” and “Switching the Operation Mode.”
(b) Tape mode selection signal: T (15–T/M)
[Classification]
Input signal
[Function] Selects the tape mode. Executes automatic operation according to the command program
entered from the tape.
[Operation] See the descriptions of “Selecting the Operation Mode” and “Switching the Operation Mode.”