B–62073E–1/04 2. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 327 –
Table 2.3.81 Axis control block data signals for use of speed command
Axis control block data
signal
Command value
or data range
Data
unit
Description
Axis control command
code signal
CDxX7 to CDxX0
0DH Specify the axis control for the velocity command.
Feed rate specify
signal
FDxX15 to FDxX0
+32767 to
–32767
(excluding 0)
rpm Specify the rotation speed at speed command by a binary
code.
Specify a positive value when the rotation direction is forward
and a negative value (a complement of 2) when reverse.
Axis control data
signal
DTxX31 to DTxX0
0 Specify 0 for the velocity command.
CAUTION Even after the velocity command is executed, the position of the tool is not lost.
The position may, however, be lost if the feedrate obtained as a result of conversion exceeds
the maximum rapid traverse rate corresponding to the set increment system.
NOTE 1 For the general description of the PMC axis control function, see Section 2.3.80.
NOTE 2 If the velocity command skip signal is set high before the block of velocity command is started,
the system ignores the signal. It must be set low while the block is being executed.
NOTE 3 If a gear is mounted between the motor and the actual axis, FDxX15 to FDxX0 determine the
speed of the servo motor instead of the speed of the axis.
NOTE 4 The feedrate may erroneous due to the following reasons:
Velocity command
AMP Motor
Detector
Gear
Axis
1
2
Fig. 2.3.81 (b)
1 The velocity command used with the PMC axis control function specifies the speed of the servo motor
that determines the feedrate. If a gear is mounted between the axis and the servo motor, the feedrate
of an axis must be specified after converting it into the speed of the servo motor. As the feedrate must
be specified by an integer, the speed of the motor obtained by rounding the feedrate may be erro-
neous.
2 The feedrate must be specified by an integer and the minimum unit in which it can be specified is calcu-
lated from the following expression. The command cannot be specified in smaller units.
F
min
: Minimum unit in which the feedrate command can be
specified
F
min
P 2
15
10
–3
P : Number of pulses per rotation of the velocity feedback
detector
The specified speed is calculated by the following expression:
F : Specified speed (integer)
F
N P 2
15
10
–3
N : Speed of the motor (rpm)
P : Number of pulses per rotation of the velocity feedback
detector
NOTE 5 In the velocity command mode, the velocity command is provided for the servo control unit.
The servo motor is started with the velocity loop gain of the servo unit. At that time, the
acceleration/deceleration loop gain and position loop gain are invalidated.