B–62073E–1/042. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 154 –
(ii) ST signal that starts program registration from a tape to memory
[Operation] When the ST signal goes high in the tape storage mode, programs are transferred from the
input device selected by parameter setting to memory. This function is enabled only when
its use is specified by parameter setting. If the function is disabled by parameter setting, the
ST signal is meaningless in the tape storage and edit mode.
This function is always treated as foreground editing. Therefore the following items should
be noted:
1 Execution of automatic operation must be reset in advance. This means that the auto-
matic operation in–progress signal OP must be low. If it is not, the ST signal is ignored.
2 When registration has terminated, the program registered last is selected as a program
to be executed in the memory mode. (Information on which program was selected before
has been lost.) Therefore, a program number must be searched for, if necessary, to se-
lect a desired program again.
3 If the selected input device is being used for background editing, the ST signal is ignored.
As registration starts, the following is also performed:
1 Automatic operation start in–progress signal STL goes high if so specified by parameter
setting. Upon completion of the registration, the STL signal goes low.
2 All programs that are not protected are deleted before registration, if so specified by pa-
rameter setting.
NOTE When registering programs from tape to memory in background editing, use external
registration start signal EXRD instead of the ST signal. In this case, if the mode is other than
the part program storage and edit mode, the registration can be performed without affecting
a program executed in the memory mode. See Section 2.3.47 for details.
(iii) ST signal to start execution of manual numerical commands
[Operation] When a high–to–low ST signal transition is made in the continuous manual feed mode,
execution of the manual numerical commands specified at that time starts. At the same time,
the following occurs:
1 Automatic operation start in–progress signal STL goes high, if so specified by parameter
setting. The STL signal goes low upon completion of the manual numerical command
execution.
Even in the continuous manual feed mode, the ST signal is ignored when:
⋅ Manual numerical commands are already being executed.
⋅ No manual numerical command has been entered, or the execution of the manual nu-
merical commands has been completed.
⋅ The M, S, T, or B function is already being executed, and such a function is also included
in the entered manual numerical commands.
⋅ The M, S, T, or B function is already being executed, and that function has been specified
alone. Or, another function specified in the same block (move command, dwell, etc.) has
already been completed. (That is, the IPEN and DEN signals are already high.)
⋅ Automatic operation stop command
SP is low.
⋅ The system is being reset. That is, ERS and RRW are high,
ESP is low, or the reset key
on the MDI panel is being held down.
⋅ An alarm has been raised.
⋅ A condition which locks manual numerical command execution is present.
Execution of the manual numerical commands that has started is stopped in the following cases.
Since all the remaining commands entered are canceled when command execution is stopped,
the command execution cannot be continued unless the commands are reentered.
⋅ All the entered commands have been executed.
⋅ Automatic operation stop signal
SP goes low.
⋅ The system is reset. That is, ERS and RRW go high, ESP goes low, or the reset key
on the MDI panel is pressed.
⋅ An alarm is raised.
⋅ The continuous manual feed mode is canceled.