B–62073E–1/04 2. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 289 –
6 When a specified tool is selected, and turret stops moving, and the control unit drives the turret clamp
signal TCLP high.
7 When TCLP goes high, the PMC mechanically clamps the turret with a shot pin or the like. After me-
chanically clamping the turret, the PMC drives the turret clamp completion signal *TECLP low.
8 When
*TECLP goes low, the control unit drives TCLP low to report the reception of *TECLP. At the
same time, the control unit places the turret axis in the servo–off state.
9 When TCLP goes low, the PMC drives
*TECLP high.
10 When
*TECLP goes high, the control unit completes a series of operations for the Txxyy command.
The procedure above (steps 6 through 10) to clamp the turret is exactly the same as in the case of
manual operation.
NOTE 1 When the auxiliary function lock is on (when the AFL signal is high), turret indexing in automatic
operation is not performed.
NOTE 2 A rapid traverse override is applicable to turret movement at rapid traverse feedrate. For
acceleration/deceleration, linear acceleration/deceleration is used.
NOTE 3 Specify G28T0yy; or G28T99yy; for automatic reference position return of the turret. This
means that when 0 (or 99, depending on the parameter) is specified as the tool number in a
G28 block, automatic reference position return is performed. Note, however, that this operation
is always performed at low–speed reference position return (using a deceleration signal). This
operation can be performed simultaneously with reference position return for other axes. The
intermediate point is always the current turret position.
NOTE 4 Once reference position return is performed, the position of the turret on the machine
corresponds to the position of the turret stored in the control unit on a one–to–one basis. After
that, each time turret indexing is performed, the position stored in the control unit is updated,
so that no reference position return is required when the power is turned on and off. This means
that the position of the turret is stored in nonvolatile memory within the NC system even when
the power is turned off. It is assumed, however, that when the power is turned off, the turret
is mechanically clamped, and turret movement is disabled. If this assumption is not satisfied,
be sure to perform reference position return after the power is turned on. If reference position
return is interrupted by a reset, emergency stop, alarm, mode switching, and so forth, be sure
to perform reference position return again. If turret indexing in automatic operation is
interrupted by a reset and so forth, and the power is turned off again without performing turret
indexing, or if the power is turned off during turret indexing, be sure to perform reference
position return. An alarm is issued when an attempt to move the turret is made in a situation
where reference position return is required.
NOTE 5 The turret cannot be moved by manual handle feed.
NOTE 6 The all–axis machine lock capability cannot be applied to the turret axis. Disable the
axis–by–axis machine lock capability for the turret axis by parameter setting.
NOTE 7 Executing reset or mode switch during turret indexing stops turret indexing; turret movement
is immediately stopped, and the clamp signal is not output. The servo–on state continues.
NOTE 8 Feed hold is not applicable to the turret axis. However, feed hold is applicable to other axes
specified in the same block.
NOTE 9 The tool number currently selected is displayed at the T–axis position (turret axis) in the
absolute coordinate (ABSOLUTE) data and relative coordinate (RELATIVE) data on the
position display screen. However, no data is displayed until the first reference position return
is performed.
NOTE 10 If a tool number specified is already indexed in automatic operation, the clamp signal and
unclamp signal are not output. However, the unclamp signal is output when the turret moves
out of the unclamped state.
NOTE 11 On the turret axis, up to 16 tool positions and the corresponding tool numbers can be specified
by parameter setting. A different value can be used for the distance between adjacent tools.
A tool number to be selected upon completion of reference position return can be specified by
parameter setting. In this case, all other tool numbers are incremented by one.
NOTE 12 Handle interrupt cannot be performed during turret indexing.