B–62073E–1/042. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 312 –
(b) Chopping speed override signals (CHP0,
CHP2, CHP4, CHP8)
[Classification]
Input signals
[Function] Apply an override to the chopping speed specified by a program.
[Operation] During chopping, a specified feedrate can be multiplied by an override specified by these sig-
nals; the resultant feedrate is the actual feedrate. The table below indicates the correspon-
dence between the states of the signals and the overrides.
CHP8
CHP4 CHP2 CHP0 Override value(%)
0 0 0 0 0
0 0 0 1 140
0 0 1 0 130
0 0 1 1 120
0 1 0 0 110
0 1 0 1 100
0 1 1 0 90
0 1 1 1 80
1 0 0 0 70
1 0 0 1 60
1 0 1 0 50
1 0 1 1 40
1 1 0 0 30
1 1 0 1 20
1 1 1 0 10
1 1 1 1 0
2.3.79 Override playback
It is possible to store the cutting feedrate override and spindle speed override set at program execution. When
that program is executed again, the stored overrides can be used.
Storing overrides is called override teaching. Using the taught overrides is called override playback.
Teaching is possible only when the memory is operating. When override teaching is performed during memory
operation, an override having the following format is inserted immediately after the current block in memory.
The override is then stored.
(Current block)
N100………………………………………………,L1F–––– R–––– S–––– ;
where
, L1 : Indicates that the following F, R, and S are commands of overrides.
F–––– : Cutting feedrate override (0 to 254, unit: 1%)
R–––– : For linear machining, the distance along the axis to the end point. For circular machining, the cen-
ter angle formed with the line passing the end point.
In playback, if the remaining distance of the axis is the value specified by R or less, or if the remain-
ing center angle of an arc is the value specified by R or less, the specified feedrate override be-
comes valid.
S–––– : Spindle speed override (50 to 120, unit: 1%)
In playback, the specified spindle speed override becomes valid from the start of the target block.
In general override playback, set the feedrate and spindle override switches on the machine operator’s panel
to 100%. If an override switch on the machine operator’s panel is set to other than 100%, the programmed
override is multiplied by the override set by that switch.