B–62073E–1/042. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 206 –
Output voltage
12
i0
{
2
i
Vi
}
E
8191
volt
where Vi = 0 when RIi is low,
Vi = 1 when RIi is high,
and E is the maximum voltage (constant) determined by the hardware.
[Operation] The control unit outputs the values of these input signals to the D/A converter every 16 ms.
(4) Diagnosis
(a) Serial interface spindle diagnosis numbers
Number
Diagnosis
1500 SIC LSI internal data
1501 SIC LSI data/PCB data/other data
1502 NC internal processing sequence data/spindle status data –1
1503 NC internal processing sequence data/spindle status data –2
1504 Torque data for No.1 spindle motor
1505 Rotational speed data for No.1 spindle motor
1506 Torque data for No.2 spindle motor
1507 Rotational speed data for No.2 spindle motor
1508 Spindle synchronization control processing sequence/other data
1509
Number of error pulses for No.1 spindle motor during spindle
synchronization control
1510
Number of error pulses for No.2 spindle motor during spindle
synchronization control
1511
Difference of the number of error pulses between the two spindles
during spindles synchronization control
(b) Detailed contents
1500 SALMI CALM CMER CER SNER FRER CRER
#7 #6 #5 #4 #3 #2 #1 #0
Data No. Data
Information in the LSI chip for the Serial Interface Controller (SIC)
CPER 1: CRC error (warning)
FRER 1: Framing error (warning)
SNER 1: Wrong transmission/reception station
CER 1: Receive error
CMER 1: No reply during automatic scanning
CALM 1: Communication alarm in the spindle amplifier
SALMI 1: System alarm in the spindle amplifier
1501 SICPOS SICTYP SICPCB
#7 #6 #5 #4 #3 #2 #1 #0
Data No. Data
SIC LSI chip, PCB, and other information
SICPCB 0: No spindle module equipped with an SIC LSI chip
1: spindle module equipped with an SLC LSI chip
SICTYP 0: SIC1 LSI
1: SIC2 LSI
SICPOS 0: Spindle module mounted on axis CPU board
1: Spindle module mounted on CNC main CPU board