B–62073E–1/042. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 146 –
(d) Reference position return deceleration signals (DEC1,
DEC2, DEC3,...)
[Classification]
Input signals
[Function] These signals decelerate the feedrate for manual reference position return so that the refer-
ence position is approached at a low feedrate. In the grid method, these signals are also used
for selecting one grid point among multiple grid points.
The deceleration signals are provided for axes in a one–to–one correspondence. A number
appended to a deceleration signal represents a controlled axis number.
DEC1
1 ……Reference position return deceleration signal for the first axis
2 ……Reference position return deceleration signal for the second axis
3 ……Reference position return deceleration signal for the third axis
:
:
:
:
[Operation] For the operation of the control unit in response to the deceleration signal, see the description
of the basic procedure for reference position return.
(e) Reference position proximity signals/reference position arrival signals (ZD1, ZD2, ZD3,...) (Multi–
axes system only)
NOTE These signals are not interface signals between the PMC and control unit.
[Classification]
Input signals
[Function] The function of these signals varies depending on the method used for reference position re-
turn.
If the grid method is used
, these signals indicate that the reference position is approached.
The next grid point is the reference position. These signals need not necessarily be used.
If they are not used, the reference position proximity signal is assumed to be always high.
So, the first grid point encountered after the deceleration signal goes high again becomes the
reference position.
If the method of using a magnetic switch is used
, these signals indicate that the reference
position has been reached. They are provided for axes in a one–to–one correspondence.
A number appended to a signal represents a controlled axis number.
ZD1
1 ……Reference position proximity/arrival signal for the first axis
2 ……Reference position proximity/arrival signal for the second axis
3 ……Reference position proximity/arrival signal for the third axis
:
:
:
:
These signals must be connected to the control unit directly, not via the PMC.
[Operation] For the operation of the control unit in response to these reference position proximity/arrival
signals, see the description of the basic procedure for reference position return.