B–62073E–1/042. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 162 –
Increase/decrease (∆F) =
Fmax
100 n
/ scale division (pulse)
where, n is a numeric value, specified by parameter setting, within a range of 1 to 127.
Fmax represents a maximum F1 digit feedrate, and is set in a parameter separately for
F1 to F4 and F5 to F9. If an increased feedrate exceeds Fmax, the feedrate is clamped
to Fmax. Conversely, if a decreased feedrate becomes lower than 0, the feedrate is
clamped to 0.
An increased or decreased feedrate is preserved even if the power is turned off.
2 When movement in automatic operation mode is not in progress according to an F1 digit
command, no F1 digit feedrate adjustment can be made. In this case, the manual pulse
generator is reserved for F1 digit feedrate adjustment; the manual pulse generator can-
not be used for axis feed.
3 In manual operation mode, this signal has no effect. Even when this signal is high, manu-
al handle feed is allowed.
NOTE The F1 digit command F0 specifies rapid traverse. There is no corresponding F1 digit setting.
2.3.21 Automatic operation test
(a) Dry run signal (DRN)
[Classification]
Input signal
[Function] This signal selects dry run to set the feedrate in automatic operation to a dry run feedrate set
by a parameter rather than to a programmed value.
[Operation] When this signal goes high, the control unit operates as described below.
1 For the cutting feedrate in automatic operation, the control unit uses a dry run feedrate
set by a parameter with a manual feedrate override applied, rather than a programmed
feedrate.
The acceleration/deceleration time constant continues to be the same as for the cutting
feed time constant.
When the rapid–traverse selection signal (RT) is also high, the tool is fed at the dry–run
feedrate to which the maximum manual feedrate override (parameter No. 2016) is ap-
plied. The dry–run feedrate, however, cannot exceed the absolute maximum cutting fee-
drate (it is clamped at the maximum cutting feedrate).
2 A parameter can also specify that a dry run feedrate be used for rapid traverse in auto-
matic operation. If the rapid traverse selection signal (RT) is also high at this time, the
original rapid traverse feedrate is used. For the acceleration/deceleration time constant,
the time constant for continuous manual feed is used during movement at a dry run fee-
drate (when RT is low); the time constant for rapid traverse is used during movement at
a rapid traverse (when RT is high).
3 If this signal is driven low from high or driven high from low during movement, the feedrate
is decelerated to 0, then is accelerated to a certain speed.
(b) Dry run check signal (MDRN)
[Classification]
Output signal
[Function] This signal reports the state of the dry run signal. The purpose of this signal is to notify the
machine of the status of the dry run switch, which can be optionally provided in the control
unit so that it can be turned on and off on the MDI panel.
[Output Condition]
This signal goes high when:
⋅ The dry run signal DRN is high
⋅ The dry run switch in the control unit is on
This signal goes low when:
⋅ DRN is low, and the dry run switch in the control unit is off