B–62073E–1/04 2. INTERFACE BETWEEN CNC AND PMC–NA OR NB
– 309 –
(b) Retrace–in–progress signal (RVSL)
[Classification]
Output signal
[Function] Notifies the PMC that retrace is in progress.
[Output Condition]
This signal goes high when:
i. The tool is in retrace with the retrace signal RVS high
This signal goes low when:
i. The tool is in forward or re–forward with the retrace signal RVS low
When the tool is in retrace, the M functions, S functions, T functions, and second auxiliary
functions are executed in the same way as when the tool is moving forward. During retrace,
this signal can be used on the PMC, if required, to prevent these functions from being
executed in the same way as when the tool is moving forward.
Particularly when an M function, S function, T function, or second auxiliary function is speci-
fied in a block containing a move command, the positions where the code signals and strobe
signal are output differ, depending on whether the tool is in forward (or re–forward) or retrace.
So, take action on the PMC by using this signal and distribution end signals DEN and IPEN
as required.
Retrace end
re-forwarding start
( Retrace signal LOW )
Position to which auxiliary function
is output during forwarding
Block in which the move command
and auxiliary function are included
Retrace start
( Retrace signal
HIGH )
Position to which auxiliary function
is output during retracing
NOTE While a tool is in retrace, the retrace–in–progress signal RVSL is sent, and the character string
RVRS blinks on the CRT screen to signal that the tool is currently in retrace. When a tool is
in re–forward, the character string RTRY blinks to signal that the tool is currently in re–forward.
The indication of RTRY continues until the tool returns to the block where retrace was started,
that is, until forward movement is resumed. When there are no more retraceable blocks, the
character string RVED blinks to signal that no further retrace can take place.