6.PARAMETERS B-64004EN/02
- 102 -
NOTE
Whether to specify this parameter by using a
diameter value or radius value depends on whether
the corresponding axis is based on diameter
specification or radius specification.
These parameters set the maximum operation range of the 1st through
64th safe position switches.
CAUTION
1 When the machine position is on the boundary of
the specified ranges (machine position =
parameter setting value), it is considered within the
specified ranges.
2 When the setting of operation range is “maximum
operation range < minimum operation range”, the
safe position switch is not output.
3 If parameter No.13920 to No.13951, No.13533 to
No.13564 are changed, please turn the power of
the machine off once.
13960 Minimum operation range of the 1st safe position switch
13961 Minimum operation range of the 2nd safe position switch
:
13990 Minimum operation range of the 31st safe position switch
13991 Minimum operation range of the 32nd safe position switch
10565 Minimum operation range of the 33rd safe position switch
10566 Minimum operation range of the 34th safe position switch
:
10595 Minimum operation range of the 63rd safe position switch
10596 Minimum operation range of the 64th safe position switch
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Real
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis