6.PARAMETERS B-64004EN/02
- 90 -
parameters are not locked, that is, when the code for safety parameters
is 0, or when the code for safety parameters is the same as the key for
safety parameters (No. 3226).
The following safety parameters are protected by a code for safety
parameters:
No.980, No.981, No.982, No.1023, No.1240, No.1838, No.1839,
No.1840, No.1841, No.1842, No.1902, No1904, No.1945, No.1946,
No.1948, No.1950, No.3021, No.3022, No.3225, No.3717, No.3797,
No.4372, No.4438, No.4440, No.4442, No.4448, No.10500,
No.10501-No.10596, No.11950-No.11957, No.11960-N0.11967,
No.11970-No.11977, No.11980-No-11987, No.13811,
No.13821-No.13829, No.13831~No.13838, No.13840-No.13843,
No.13880-No.13911, No.13920-No.13951, No.13960-No.13991
NOTE
Once parameters are locked, the lock must be
released or memory must be cleared before the
safety parameters can be modified. Moreover, the
code for the safety parameters cannot be modified
in locked condition. Be careful when setting a code
for safety parameters.
3226 Key for safety parameters
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word
[Valid data range] 0 to 99999999
When the same value as the code for safety parameters No.3225 is set
in this parameter, the key is opened to enable modifications to the
safety parameters. The value set in this parameter is not displayed.
When the value other than 0 is set to the code for safety parameters
No.3225 and the value is different from this parameter, the key is
locked and the safety parameters can not be modified.
When the power is turned off, the value set in this parameter is cleared
to 0. Then the power-off results in the locked state.