B-64004EN/02 3.SAFETY FUNCTIONS
- 15 -
3.1 APPLICATION RANGE
The dual check safety function assumes the following configuration:
A) At least, one protective door is provided.
B) If protective door is closed, safety is assured.
When the operator makes a request to open the protective door, the
safety functions are enabled, and the protective door can be unlocked.
While the protective door is open, the active safety functions assure
safety. When the request to open the protective door is canceled, the
protective door is locked, and the safety functions are disabled.
The dual check safety function provides these safety functions while
the protective door is open, as described above. Some of the safety
functions continue working while the protective door is closed.
WARNING
Each machine tool builder should take measures to
assure safety while the protective door is closed
and to ensure safety related to a rotation axis and
travel axis. At the same time, safety measures for
the FANUC servo motor or spindle motor need to
be taken, while the door is open.
Safety function
The dual check safety function has the following safety functions:
• Safe-related I/O signal dual monitoring
Emergency stop input, protective door open/close state,
relay state for turning off the MCC
Output signal for shutting off the power (turning the MCC off)
To detect the latent cause of an abnormal state of this output, a
MCC off Test must be made.
• Spindle motor
Safe speed monitoring
• Servo motor
Safe speed monitoring
Safe machine position monitoring
Safe position error monitoring