B-64004EN/02 6.PARAMETERS
- 87 -
NOTE
The same value is applied for each path that
belongs to a machine group.
1950 Brake signal timer
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word machine group
[Unit of data] msec
[Valid data range] 0 to 32767
Set a time period from when CNC CPU and Servo CPU in Dual
Check Safety function detects that the servo amplifier is ready (MCC
on state) until Safety Brake signal (*BRKx) goes 1 (brake release
enabled).
NOTE
The same value is applied for each path that
belongs to a machine group.
3021
Address to which an axis signal is assigned
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 0 to 7, 10 to 17, 20 to 27, ... , 90 to 97
For each axis of the CNC, set a PMC interface address.
Set a value according to the tables below.
Value of parameter No. 3021 (tens digit)
Setting
value
Input signal address Output signal address
0 G0000 to G0999 F0000 to F0999
1 G1000 to G1999 F1000 to F1999
・・・
9 G9000 to G9999 F9000 to F9999
Value of parameter No. 3021 (ones digit)
Setting
value
Input signal address Output signal address
0 #0 #0
1 #1 #1
・・・
7 #7 #7