A. Directives, Standards and Technical Conditions for 3
rd
Party Servo /
B-64004EN/02 APPENDIX Spindle Motors & Encoders when Applying FANUC / GE Fanuc Dual-check Safety
- 157 -
A.3 SPINDLES
A.3.1 Spindle Motors – Driven by FANUC / GE Fanuc Spindle
Amplifier
• 3-phase AC asynchronous motor, compact type or built-in type
• Input voltage: 200 V AC or 400 V AC
• Winding switching available, e.g. start/delta or 2 different
windings like star/star
• Number of pole-pairs: 1, 2, 3 or 4
• Rated current must be equal or less than rated current of Spindle
Amplifier.
• Maximum current must be equal or less than maximum current of
Spindle Amplifier.
• Applicable maximum speed of spindle motors
Ö maximum speed = 60 / pole-pairs * max output freq.
A.3.2 Spindle Encoder – Speed / Position Feedback Sensor
Embedded in Motor
• Signal type: A/B-phase sine-wave for speed feedback
Z-phase (one-per-rotation) signal for position
feedback
• Signal specifications: see Attachment 1