3.SAFETY FUNCTIONS B-64004EN/02
- 26 -
Guard Open Request signal and Guard Unlock signal
*OPIHB
F
24V
X
Door open request
Ladder
Ladder
ORQ-I
ORQ
Protective
door lock
G
Y
Protective door
CNC(PMC)
F
RSVx
RSPx
POSEx
F
The figure shows a sample connection of the protective door open
request switch and the guard unlock signal. In the normal state, the
door lock state is changed as follows before the safety monitoring
state is established.
Door lock state transition
ORQ-I ORQ *OPIHB RSVx
RSPs
POSEx Protective
door lock
(*SGOPN)
A
0 0 0 Locked A protective door open request is
not made, and the door is
locked.
Normal
operating
state
B
1 0 0 Locked A guard open request is made.
C1
1 1 0 Locked The request is transferred to the
CNC.
C2
1 1 1 Locked The CNC receives the request.
D
1 1 1 1 1 Locked Reference point is established
and a safe speed check, a
machine position check and a
position error check prove that
there is no failure and that the
CNC can enter the safe state.
E
1 1 1 1 1 Unlocked
(*SGOPN=0)
The actual safety door is
unlocked.
Operations can be performed
with the door open.
Safety
function is
enabled.
D
1 1 1 1 1 Locked The door is closed and locked
again.
F
0 1 1 1 1 Locked The guard open request is
canceled.
G
0 0 1 1 1 Locked The request is transferred to the
CNC.
A
0 0 0 Locked The CNC receives the request
and exits from the safe state.