10.SAMPLE SYSTEM CONFIGURATION B-64004EN/02
- 138 -
This section describes the operation of various guard monitoring limit
switches with lock mechanism and safety relays.
State transition of components
SW1 SW2 SW3 RY1 RY2 RY3 *SGOPN
(*VLDVx,
*VLDPs)
1 Guard closed
Guard locked
CLOSE CLOSE CLOSE ON ON OFF 1
2 Guard closed
Guard unlocked
CLOSE CLOSE OPEN OFF ON OFF 0
3 Guard opened
Guard unlocked
OPEN OPEN OPEN OFF OFF ON 0
4 Guard opened
Guard locked
OPEN OPEN CLOSE OFF OFF ON 0
1
Guard closed
Guard locked
CLOSE CLOSE CLOSE ON ON OFF 1
In a normal operation, the transition of 1, 2, 3, 4,1, 2, and so on is
repeated.
RY3 detects whether RY1 and RY2 contacts are made. If an unusual
event is detected, *SGOPN input is turned off.
NOTE
The guard state is monitored, and the guard state
signal (*VLDVx,*VLDPs) affects the dual check
safety function.
The illustrated sample system determines that the
guard is open (sets *VLDVx and *VLDPs to 0)
when the guard is unlocked.
When the guard open request signal (ORQ) is
accepted, CNC will negate the guard open inhibit
signal (*OPIHB).
Machine tool builder can create the signal to
release the guard-lock by his ladder program,
when the following conditions are met.
*OPIHB=1, RSVx and RSPs to be refered=1 and
the safety conditions of the machine