B-64004EN/02-01
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
4/4
Date
Design
Descri
tion
Date
FANUC Series 30i/31i32i -A, 31i-A5
About the setting of the velocity parameter
when a diameter is specified
NOTE
In case of a diameter is specified, set the value of two times to this
parameter.
Ex: In case of 10mm/min, set “20.” to this parameter,
In case of velocity control, set the value calculated by the following
formula to this parameter when R(min
-1
) is the velocity, at which the axis
is regarded as stopped.
Setting value = R * PLS * Minimum data unit (Machine unit) * N / CMR
PLS: Pulse per one revolution of motor (Detection unit)
CMR: Command multiplier
N: In case of diameter specification, N=2.
In other case, N=1.
Minimum data unit: Refer to “STANDARD PARAMETER
SETTING TABLE”.