B-64004EN/02 7.START-UP
- 113 -
Parameter setting Meaning
1023 Servo axis number of each axis
1240 Coordinates value of the reference position in the
machine coordinate system
1838 Position deviation limit for each axis in moving state
1839 Position deviation limit for each axis in stopped state
1840 Position deviation limit for each axis in servo-off state
1841 Position deviation limit of each axis in moving state
during other than Dual Check Safety monitoring (for
Dual Check Safety Function)
1842 Position deviation limit of each axis in stopped state
during other than Dual Check Safety monitoring (for
Dual Check Safety Function)
1904#6 Enable safety function for each axis
1945 Timer for safety input signal check
1946 Timer for MCC off Test
1948 Timer 2 for MCC off
1950 Break signal timer
3717 Motor number to each spindle
3797#0 Enable safety function for each spindle
4372 Safety speed 1 on each spindle
4438 Safety speed 2 on each spindle
4440 Safety speed 3 on each spindle
4442 Safety speed 4 on each spindle
4448 Speed regarded as spindle stop for Dual Check Safety
13821 Safety speed 1 on each axis
13822 Safety speed 2 on each axis
13823 Safety speed 3 on each axis
13824 Safety speed 4 on each axis
13825 Speed regarded as axis stop for Dual Check Safety
13831 Safety position 1 (+ direction) on each axis
13832 Safety position 1 (- direction) on each axis
13833 Safety position 2 (+ direction) on each axis
13834 Safety position 2 (- direction) on each axis
13835 Safety position 3 (+ direction) on each axis
13836 Safety position 3 (- direction) on each axis
13837 Safety position 4 (+ direction) on each axis
13838 Safety position 4 (- direction) on each axis
Step 4
If alarm SV0478 or SV0496 occurs, set the parameter No.2212#4 is
set to “1” and then set to “0”.
Then turn off the CNC and the amplifier. And turn on the CNC and
the amplifier.
Step 5
Execution of general machine tests
Axis and spindle optimization
Dual check safety function adjustment (safety limitation speed, safety
machine position, Safe position error monitoring)