6.PARAMETERS B-64004EN/02
- 80 -
6.5 PARAMETERS
0980 Machine group number of each path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 1 to 3
Set the machine group number which each path belongs.
NOTE
When 0 is set, each path is assumed to belong to
machine group 1.
0981 Absolute path number of each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 1 to 10
Set the path to which each axis belongs.
NOTE
When 0 is set each axis is assumed to belong to path
1.
0982 Absolute path number of each spindle
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte spindle
[Valid data range] 1 to 10
Set the path to which each spindle belongs.
NOTE
When 0 is set each axis is assumed to belong to path
1.