5.I/O SIGNALS B-64004EN/02
- 54 -
CAUTION
1 The Emergency Stop signal for DCS PMC is
assigned to each machine group, like the signal for
PMC.
<X008#4> for 1
st
machine group
<X008#0> for 2
nd
machine group
<X008#1> for 3
rd
machine group
2 The related parameter must be set in order to
perform the controlled stop of a servo motor. If the
parameter is not set, a servo motor is stopped by
dynamic brake control just after an emergency stop
is detected.
3 A spindle motor is slowed down by the command
(PMC ladder program). If the PMC does not
command to slow down, the spindle motor
continues rotating at the speed prior to
power-down and runs by inertia (and eventually
stopping in the end). When safety function is active
(protective door is open) and abnormal speed is
given due to the trouble of PMC, the spindle is
brought into safe stop state.
4 The Emergency Stop signals for every machine
group, <X008#4> <X008#0> <X008#1>, are
checked doubly in PMC and DCS PMC.
WARNING
A machine tool builder must make the ladder to
control to open and shut protective door in
emergency stop state. For instance, a machine tool
builder must make the ladder program for
procedure to inhibit to open the protective door in
emergency stop state.
IMPORTANT
1 Emergency stop button must fulfill the Standard
IEC60947-5-1.This is mandatory.
2 As MCC Off signal (*MCF) is effective for each
machine group, MCC is controlled per a machine
group. Then, although the Emergency Stop signal
by G signal is effective for each path, design to
turn on Emergency Stop by G signal of all paths in
a machine group at the same time.