3.2 MOUNTING A COOLING PLATE AND CONNECTING A
COOLING TUBE
This section describes how to mount a cooling plate on the linear
motor and connect the cooling tube.
3.2.1 LiS 300A1/4, LiS 600A1/4, LiS 900A1/4, and LiS 1500B1/4
When performing forced air cooling or forced water cooling with
L
iS 300A1/4, LiS 600A1/4, and LiS 900A1/4, mount a cooling plate
between the slider and table so that the cooling tube extends in the
same direction as the power line. The mounting hole pitch of a cooling
plate is the same as the mounting screw pitch of the coil slider. A
cooling plate is inserted and secured by pulling the coil slider toward
the table with setscrews. Then, connect an external chiller to the
cooling tube with tube joints.
Table
Cooling plate
Coil slider
Power
line
Setscrew
Cooling tube
NOTE
1 The cooling plate is optional. The size of a cooling
plate varies from one model to another. Order an
appropriate cooling plate according to the motor
model used.
2 When an incremental linear encoder is used, a
magnetic pole sensor is required. When a cooling
plate is mounted, the method of mounting a
magnetic pole sensor changes. See Section 3.5,
"MOUNTING A MAGNETIC POLE SENSOR".