2.SPECIFICATIONS SPECIFICATIONS B-65382EN/02
- 66 -
2.4.7 Position Detection Circuit
Position detection circuit one-output type (A860-0333-T201)
Position detection circuit two-output type (A860-0333-T202)
Position detection circuit one-output type (A860-0333-T301)
for Distance corded linear encoder
Position detection circuit two-output type (A860-0333-T302)
for Distance corded linear encoder
NOTE
To use an incremental linear encoder, a position
detection circuit is required. A magnetic pole
sensor described in the previous subsection is also
required. When an absolute linear encoder is used,
neither is required.
TO: SERVO AMPLIFIER
PPROX. 56
TO: LINEAR
ENCORDER
TO: MAGNETIC POLE
SENSOR
PPROX. 70
Mass: 0.7 kg (body only, not including the cable)
NOTE
1 Use the one-output type (A860-0333-T201 or T301) in a typical configuration. Use
the two-output type (A860-0333-T202 or -T302) only when signals must branch off
from one linear encoder.
2 To connect the position detection circuit to a magnetic pole sensor, prepare cable
K4. The magnetic pole sensor dedicated to the LiS 300A1/4, LiS 600A1/4, and
LiS 900A1/4 is supplied with a cable.
3 For the cable between the linear encoder and position detection circuit, contact the
relevant linear encoder manufacturer.
4 To connect the position detection circuit to a servo amplifier, prepare cable K2.
5 For details of each cable, see Section 2.5, "CABLES."