3.ASSEMBLY HANDLING, DESIGN, AND ASSEMBLY B-65382EN/02
- 174 -
3.3 POWER LINE AND THERMOSTAT LINE CONNECTION
This section describes the method of linear motor power line
connection and thermostat line connection. Connect the leads
correctly according to the model used.
3.3.1 LiS 300A1/4, LiS 600A1/4, and LiS 900A1/4
For the L
iS 300A1/4, LiS 600A1/4, and LiS 900A1/4, the power
lines and thermostat lines directly jut out of the coil slider. The
specifications of the lines are shown below.
Line type
Sheath
color
Conductor cross
section (mm
2
)
Average outside
diameter (mm)
Power line (U phase) Red 2.0 2.6
Power line (V phase) White 2.0 2.6
Power line (W phase) Black 2.0 2.6
Power line (ground)
Green /
Yellow
2.0 2.6
Thermostat line 1 Black 0.35 1.28
Thermostat line 2 Black 0.35 1.28
NOTE
1 The length of the power lines and thermostat lines
is approximately 350 mm.
2 The power lines and thermostat lines have no
crimp contacts.
3 The thermostat lines have no polarities.
4 The cables are not movable ones. When the coil
slider is movable, be sure to connect it to a
movable relay cable.