B-65382EN/02 SPECIFICATIONS 2.SPECIFICATIONS
- 67 -
2.5 CABLES
2.5.1 Overview of Connection
When using an incremental linear encoder, connect the cables for the
linear motor as follows. When using an absolute linear encoder,
directly connect the signal cables for the linear encoder to the servo
amplifier since the magnetic pole sensor and position detection circuit
are not used.
Power line
Thermostat line
Servo amplifier
Magnet plate Coil slider
Magnetic pole sensor
Linear encoder
Position detection circuit
FSSB
Cable
number
Connection Ordering information and remarks
K1
Between the CNC and servo
amplifier
For details, refer to the related CNC connection
manual.
K2
Between the position
detection circuit and servo
amplifier
Only a cable with the standard length (7 m) can be
ordered. Other cables must be prepared by yourself.
Ordering information: A06B-6061-K802
Length: 7 m
K3
Between the motor and servo
amplifier (power line)
For details, see Part III, "HANDLING, DESIGN, AND
ASSEMBLY."
K4
Between the magnetic pole
sensor and position detection
circuit
For the L
iS 300A1/4 to LiS 900A1/4, a cable with a
length of 4 m comes with the magnetic pole sensor.
For the L
iS 1500B1/4 or later, only a cable with the
standard length (7 m) can be ordered. Other cables
must be prepared by yourself.
Ordering information: A06B-6061-K801
Length: 7 m
K5
Between the linear encoder
and position detection circuit
Contact the relevant linear encoder manufacturer or
dealer.
K6 Thermostat line wire
For details, see Part III, "HANDLING, DESIGN, AND
ASSEMBLY."
NOTE
FANUC does not recommend use of relayed signal
lines. Relay signal lines on your own responsibility
if required. If it is absolutely necessary to relay