2.2 FROM File Naming Convention
Data files registered in the CNC follow an own naming convention. Even they are loaded with a
different name, the CNC displays these files according the convention in the Boot Menu.
The naming is identical for both CNC configurations (Display Unit/Panel i)
File Name Contents File Type
NC BASIC CNC System Software System File
NC □BSIC CNC System Software (add. File) System File
NC□OPTN Optional CNC System Software System File
DGB0SRVO Servo Software System File
GRAPHIC Graphic System Software System File
PS□B406J PMC Control Software System File
ETH2 EMB Control Software for Ethernet
Embedded Port
System File
ETHE Control Software for Fast
Ethernet Card
System File
MINFO Maintenance Information Data Data File
MNT2SRVO Monitor Software for Dual Check
Safety
System File
FLNT FL-Net Firmware System File
IO2 OPT1 Communication Setting Software
FL-Net
System File
PMDM Profibus Master Firmware System File
COM0OPT1 Profibus Control Software System File
TMF Tool Management Function System File
CEX□□□□□ C-Executor File
Application File
PDx□□□□ Macro Executor File
Application File
PMC-SB PMC Program
Application File
CEX0FPDT FANUC Picture Screen Data
Application File
□ – one digit number or character depending on file type
Table 2: Naming Convention of CNC files
It is dependent on the CNC-Unit, which system files are stored in the FROM.
I.e., for those CNC station, which do not have Profibus Board applied, the Profibus Software is
missing.
Moreover, it is dependent on the application of the CNC, whether application files like C-Executor
or Macro-Executor are used. At least the PMC Ladder Program can be found at every CNC.
File Name: Backup_Guidance_EN21.doc
Created by: Olaf Sklepik on 20-Apr-05
Approved by: n/a
Page 10 of 72