B–63323EN/03
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
103
Alarm detection
address and bit
DO address Location
Xm+15.0 Yn+0 Basic module
Xm+15.1 Yn+1 Basic module
Xm+15.2 Yn+2 Extension module 1
Xm+15.3 Yn+3 Extension module 1
Xm+15.4 Yn+4 Extension module 2
Xm+15.5 Yn+5 Extension module 2
Xm+15.6 Yn+6 Extension module 3
Xm+15.7 Yn+7 Extension module 3
NOTE
This function is supported by neither the 2A–output module
nor the analog input module.
2A–output and analog input module assignment
The 2A–output and analog input modules can be allocated in any of the
spaces for expansion modules 1, 2, and 3. It is also possible to allocate
up to three 2A–output or analog input modules in all these module spaces.
If the MPG interface is required, however, it occupies expansion module
1, and therefore, neither a 2A–output nor analog input module can be
allocated in this module space.
Because no DI is available in the 2A–output module, the DI space
corresponding to the 2A–output module cannot be used. For example, if
the 2A–output module is allocated in the space for expansion module 2,
it is impossible to use a space between Xm+6 and Xm+8. (This will not
shift the space for other modules; the DI space for expansion module 3
remains between Xm+9 and Xm+11.)