G. TERMINAL MODULE
B–63323EN/03
520
Ambient
temperature
At operation 0_C to 55_C
Storing or transporting –20_C to 60_C
Temperature
change
Max. 0.3_C/min
Relative humidity Normally 75% or less (Relative humidity)
Short time (Within one month) 95% or less (Relative humidity)
Vibration Operating 0.5G or less
Environment Normal FA atmosphere (The examination is necessary when using
the system under environments with higher degree of dust, cool-
ant, or organic solution.)
Other requirements Use this module in a cabinet that is always completely closed.
Item Specification Remarks
Terminal module A03B–0815–C020
Connection cable A03B–0815–K020 0.3m
(Between connector panel I/O module
and terminal module.)
A03B–0815–K021 1m
A03B–0815–K022 2m
Item Specification Remarks
DI points 24 points Terminal block connection
DO points 16 points Terminal block connection
Terminal Rated voltage 250V Screw up type
block
Rated thermal
current
10A
Adaptation wire 1.25mm
2
Tightening torque 0.5 to 0.75N@m
24VDC"10% is supplied from terminal block XT150A and XT150B
(The "10% tolerance includes momentary and ripple currents.)
For detailed power supply rating of connector panel I/O module, refer to
connection manual of connector panel I/O module.
For detailed input/output signal specifications, refer to connection
manual of connector panel I/O module.
G.5
SPECIFICATIONS
G.5.1
Installation
Specifications
G.5.2
Ordering
Specifications
G.5.3
Module Specifications
G.5.4
Power Voltage
G.5.5
DI/DO (Input/output
Signal Specification)